HOME > Solutions(Download data sheets and manuals ) > load cell graphic panel meter
(load cell and pluse signal)
SolutionsDownload data sheets and manuals
-
Search by Keywords
-
Search by Categories
Series changed Products / Discontinued Products
G1□□1
:load cell graphic panel meter
(load cell and pluse signal)
Graphic panel meter for load cell measurement with 2-channel input
●Production discontinued on July 31,2021
(With SD function planned to end production on March 31,2019)
Features
・With 2 channel of load cell & pulse signal input function
・Waveform comparison and numeric comparison available
・Self-diagnosis function of load cell available
・CE approved
Download
Date Sheets | Specification sheet |
---|---|
Manuals | Manual(Simple) Manual(setup) Manual(Detail) |
Dimensions | Dimensions |
Others | unavailable now |
Specifications
Input | Load cell(350Ω) Freaquency measurement 0.1Hz to 50kHz Open collector : L : 1.5V or less, H : 3.5V or more Line driver : ±2V or more(differential voltage) |
---|---|
Output | ※Specification depends on model codes. Comparative output×5(HH/HI/GO/LO/LL) Open collector・・・DC30V 30mA Analog output×1 DC voltage/DC current BCD output×1 Open collector・・・DC30V 15mA Communication output×1 RS-232C/RS-485 |
Network | RS-232C RS-485 |
Power | AC100~240V DC12~48V |
Accuracy | Load cell:0.25~1.0μV/digit |
Dielectric strength | AC1500V |
Weight | Approx.1000g |
Standards & Approvals | EN61326-1 EN61010-1 |
Dimensions(HWD) | 96×100×153mm |
Operating temperature/humidity | 0~+40℃ 35~85%RH |
Panel size(HW) | 96×100mm |